{"id":6234,"date":"2023-03-17T14:54:15","date_gmt":"2023-03-17T13:54:15","guid":{"rendered":"https:\/\/cn.quintustechnologies.com\/?post_type=faq&#038;p=6234"},"modified":"2025-01-28T15:49:58","modified_gmt":"2025-01-28T14:49:58","slug":"what-parameters-should-be-used","status":"publish","type":"faq","link":"https:\/\/cn.quintustechnologies.com\/en\/faq\/what-parameters-should-be-used\/","title":{"rendered":"What parameters should be used in HIP?"},"content":{"rendered":"<p>Modern standard HIP equipment operates up to 2000 \u00b0C and 200 MPa pressure from argon or nitrogen gas. The parameters chosen are always material-specific, keeping in mind that the elevated pressure will lower the temperature needed to achieve the same effect in a pressureless environment. This can be utilized for e.g., minimizing grain growth in sintering, avoiding part surfaces sticking, controlling microstructures, etc.<\/p>\n","protected":false},"menu_order":0,"template":"","categories-faq":[217],"class_list":["post-6234","faq","type-faq","status-publish","hentry","categories-faq-material-densification"],"acf":[],"_links":{"self":[{"href":"https:\/\/cn.quintustechnologies.com\/en\/wp-json\/wp\/v2\/faq\/6234","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cn.quintustechnologies.com\/en\/wp-json\/wp\/v2\/faq"}],"about":[{"href":"https:\/\/cn.quintustechnologies.com\/en\/wp-json\/wp\/v2\/types\/faq"}],"wp:attachment":[{"href":"https:\/\/cn.quintustechnologies.com\/en\/wp-json\/wp\/v2\/media?parent=6234"}],"wp:term":[{"taxonomy":"categories-faq","embeddable":true,"href":"https:\/\/cn.quintustechnologies.com\/en\/wp-json\/wp\/v2\/categories-faq?post=6234"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}